Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
J Appl Lab Med ; 5(2): 320-331, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32445386

RESUMO

BACKGROUND: The current biomarkers for diagnosis and monitoring of injured and diseased skeletal muscles, such as creatine kinase (CK), have limited tissue specificity and incapability to differentiate between pathological and physiological changes. Thus, new biomarkers with improved diagnostic accuracy are needed. Our aim was to develop and validate a novel assay for skeletal troponin I (skTnI), and to assess its clinical performance in patients with idiopathic inflammatory myopathies (IIM). METHODS: A two-step fluoroimmunoassay was used to analyze samples from healthy reference individuals (n = 140), patients with trauma (n = 151), and patients with IIM (n = 61). RESULTS: The limit of detection was 1.2 ng/mL, and the upper reference limit (90th percentile) was 5.2 ng/mL. The median skTnI concentrations were

Assuntos
Biomarcadores , Miosite/sangue , Miosite/diagnóstico , Troponina I/sangue , Adulto , Idoso , Bioensaio/métodos , Bioensaio/normas , Feminino , Fluorimunoensaio/métodos , Fluorimunoensaio/normas , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/metabolismo , Músculo Esquelético/patologia , Miosite/etiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
2.
J Immunol Methods ; 470: 15-19, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31004578

RESUMO

Neutrophil gelatinase-associated lipocalin (NGAL) is a promising biomarker for diagnosing acute kidney injury (AKI). Currently, there are few assays for determining NGAL and they are complex, time-consuming or expensive. We aimed to establish an efficient immunoassay to measure NGAL in human urine simply and rapidly. A novel immunoassay for NGAL determination was established by combining a dissociation-enhanced-free time-resolved fluoroimmunoassay (TRFIA) and immunomagnetic separation. Based on a "sandwich"-type immunoassay format, analytes in samples were captured by a pair of monoclonal antibodies (mAb) in which one mAb was coated in magnetic beads and the other mAb was labeled with europium(III) chelate microparticles (CM-EUs) as "fluorescent reporters". NGAL concentrations were determined in a linear range (10-1500 ng mL-1) with a limit of detection of 0.32 ng mL-1. The reproducibility, recovery, and specificity of our TRFIA were acceptable. Our method was compared with that of a chemiluminescence immunoassay (CMIA) using 115 urine samples, and the results showed good correlation (R2 = 0.8677). We expect our novel method to be useful for the early diagnosis of AKI.


Assuntos
Injúria Renal Aguda/diagnóstico , Fluorimunoensaio/métodos , Imunoconjugados/química , Separação Imunomagnética/métodos , Lipocalina-2/urina , Injúria Renal Aguda/fisiopatologia , Injúria Renal Aguda/urina , Anticorpos Monoclonais/química , Biomarcadores/urina , Diagnóstico Precoce , Fluorimunoensaio/normas , Humanos , Separação Imunomagnética/normas , Limite de Detecção , Imãs/química , Compostos Organometálicos/química , Reprodutibilidade dos Testes
3.
Scand J Clin Lab Invest ; 79(1-2): 80-85, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30638079

RESUMO

Osteoporosis is a disease where increased bone weakness increases the risk of a broken bone. Until a broken bone occurs, there are typically no symptoms. Osteoporosis affects more than 75 million people in the United States, Europe and Japan. The diagnosis of osteoporosis is primarily determined by measuring bone mineral density using dual-energy X-ray absorptiometry, but for men under 50 years of age, premenopausal women should not be made on the basis of densitometric criteria alone. Bone biomarkers are a useful tool in detecting osteoporotic. A two-step dual-label time-resolved fluorescence immunoassay (TRFIA) was developed for the simultaneous detection of serum C-terminal telopeptide (ß-CTX) and amino-terminal propeptide (P1NP) of Type I procollagen in a single run. The performance of this assay was first evaluated using clinical serum samples, and then compared with commercialized kits. The sensitivity of this assay for ß-CTX was 1 ng/L (dynamic range, 0-1000 ng/L), and the sensitivity for P1NP detection was 1 µg/L (dynamic range, 1-1000 µg/L). High correlation coefficients (R) were obtained between the present dual-label TRFIA and commercially available kits (R = 0.99 for ß-CTX and P1NP). The present dual-label TRFIA has high sensitivity, specificity and accuracy in clinical sample analysis. It is a good alternative to the single-label diagnostic methods.


Assuntos
Colágeno Tipo I/sangue , Fluorimunoensaio/normas , Osteoporose/diagnóstico , Fragmentos de Peptídeos/sangue , Peptídeos/sangue , Pró-Colágeno/sangue , Adulto , Idoso , Anticorpos Monoclonais/química , Biomarcadores/sangue , Densidade Óssea , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/sangue , Osteoporose/fisiopatologia , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos
5.
PLoS One ; 13(9): e0201205, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30180167

RESUMO

BACKGROUND: Multiplex assays are increasingly applied to analyze multicomponent signatures of human immune responses, including the dynamics of cytokine and chemokine production, in observational as well as interventional studies following treatment or vaccination. However, relatively limited information is available on the performance of the different available multiplex kits, and comparative evaluations addressing this important issue are lacking. STUDY DESIGN: To fill this knowledge gap we performed a technical comparison of multiplex bead assays from 4 manufacturers, each represented by 3 different lots, and with the assays performed by 3 different laboratories. To cross compare kits directly, spiked samples, biological samples and a newly made reference standard were included in all assays. Analyses were performed on 324 standard curves to allow for evaluation of the quality of the standard curves and the subsequent interpretation of biological specimens. RESULTS: Manufacturer was the factor which contributed most to the observed variation whereas variation in lots, laboratory or type of detection reagent contributed minimally. Inclusion of a common reference standard allowed us to overcome observed differences in cytokine and chemokine levels between manufacturers. CONCLUSIONS: We strongly recommend using multiplex assays from the same manufacturer within a single study and across studies that are likely to compare results in a quantitative manner. Incorporation of common reference standards, and application of the same analysis method in assays can overcome many analytical biases and thus could bridge comparison of independent immune profiling (e.g. vaccine immunogenicity) studies. With these recommendations taken into account, the multiplex bead assays performed as described here are useful tools in capturing complex human immune-signatures in observational and interventional studies.


Assuntos
Citocinas/sangue , Citocinas/imunologia , Kit de Reagentes para Diagnóstico/normas , Feminino , Fluorimunoensaio/normas , Humanos , Masculino , Padrões de Referência
6.
Methods Mol Biol ; 1735: 457-465, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29380336

RESUMO

In metabolic diseases such as obesity and type 2 diabetes mellitus, the conversion of proinsulin to mature insulin can be impaired. This could mean that insulin molecules with lower activity toward the insulin receptor can be released under conditions of high metabolic demand, resulting in an inadequate glucoregulatory response. The chapter describes a fluorescent monoclonal antibody-based protocol for measurement of human proinsulin and the proinsulin conversion intermediates (split proinsulins). An example assay is presented using serum from non-diabetic, normal body mass index individuals.


Assuntos
Fluorimunoensaio , Proinsulina/sangue , Fluorimunoensaio/métodos , Fluorimunoensaio/normas , Humanos , Sensibilidade e Especificidade
7.
J Thromb Haemost ; 15(10): 1971-1976, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28795528

RESUMO

Essentials Immunologic methods detect factor VIII (FVIII) antibodies in some inhibitor-negative specimens. Specimens were tested by modified Nijmegen-Bethesda assay (NBA) and fluorescence immunoassay. The NBA with preanalytical heat inactivation detects FVIII inhibitors down to 0.2 NBU. IgG4 frequency validates the established threshold for positivity of ≥ 0.5 NBU for this NBA. SUMMARY: Background The Bethesda assay for measurement of factor VIII inhibitors called for quantification of positive inhibitors by using dilutions producing 25-75% residual activity (RA), corresponding to 0.4-2.0 Bethesda units, with the use of 'more sensitive methods' for samples with RA closer to 100% being recommended. The Nijmegen modification (Nijmegen-Bethesda assay [NBA]) changed the reagents used but not these calculations. Some specimens negative by the NBA have been shown to have FVIII antibodies detectable with sensitive immunologic methods. Objective To examine the performance at very low inhibitor titers of the Centers for Disease Control and Prevention (CDC)-modified NBA (CDC-NBA), which includes preanalytic heat inactivation to liberate bound anti-FVIII antibodies. Methods Specimens with known inhibitors were tested with the CDC-NBA. IgG4 anti-FVIII antibodies were measured by fluorescence immunoassay (FLI). Results Diluted inhibitors showed linearity below 0.4 Nijmegen-Bethesda units (NBU). With four statistical methods, the limit of detection of the CDC-NBA was determined to be 0.2 NBU. IgG4 anti-FVIII antibodies, which correlate most strongly with functional inhibitors, were present at rates above the background rate of healthy controls in specimens with titers ≥ 0.2 NBU and showed an increase in frequency from 14.3% at 0.4 NBU to 67% at the established threshold for positivity of 0.5 NBU. Conclusions The CDC-NBA can detect inhibitors down to 0.2 NBU. The FLI, which is more sensitive, demonstrates anti-FVIII IgG4 in some patients with negative (< 0.5) NBU. The sharp increase in IgG4 frequency between 0.4 and 0.5 NBU validates the established threshold for positivity of ≥ 0.5 NBU for the CDC-NBA, supporting the need for method-specific thresholds.


Assuntos
Autoanticorpos/sangue , Centers for Disease Control and Prevention, U.S./normas , Fator VIII/imunologia , Fluorimunoensaio/normas , Hemofilia A/imunologia , Imunoglobulina G/sangue , Fator VIII/uso terapêutico , Hemofilia A/sangue , Hemofilia A/diagnóstico , Hemofilia A/tratamento farmacológico , Humanos , Limite de Detecção , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estados Unidos
8.
Sci Rep ; 7(1): 7288, 2017 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-28779162

RESUMO

Replacement of the in vivo rabies vaccine potency test (NIH test) by in vitro methods had been discussed by several researcher including WHO expert working groups. In this paper, a time-resolved fluoroimmunoassay (TRFIA) for the assay of rabies virus glycoprotein in rabies vaccine was first established to estimate the rabies vaccine potency by using specific monoclonal antibody that only recognized the native, trimeric and immunogenic form of rabies virus glycoprotein. Potency of the rabies virus glycoprotein was assayed with satisfactory performance under optimal conditions, and the method demonstrated satisfactory results when applied in practical samples. The correlation coefficient of potency values obtained from the present TRFIA and ELISA was 0.912, and 0.903 for those from the present TRFIA and NIH test. These preliminary results confirmed that this TRFIA can replace ELISA with higher performance, and could be a promising replacement of the NIH test. Based upon these results, the present TRFIA seemed to be a convenient tool for evaluating rabies vaccine potency and its products at different stages accordingly.


Assuntos
Antígenos Virais/imunologia , Fluorimunoensaio , Glicoproteínas/imunologia , Vírus da Raiva/imunologia , Proteínas Virais/imunologia , Animais , Anticorpos Monoclonais/imunologia , Anticorpos Antivirais/imunologia , Linhagem Celular , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática , Feminino , Fluorimunoensaio/métodos , Fluorimunoensaio/normas , Humanos , Camundongos , Raiva/prevenção & controle , Vacina Antirrábica/imunologia , Sensibilidade e Especificidade , Potência de Vacina
9.
Platelets ; 28(3): 242-248, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28102735

RESUMO

There is increasing clinical interest in extracellular vesicles (EV) for diagnostic and treatment purposes. This review provides an overview of bulk immunoassays to analyse EV. Western blot and enzyme-linked immunosorbent assay are still the two predominant bulk immunoassays. Recently, new assays have become available that can detect exposure to EV concentrations that are up to 10,000-fold lower. This is advantageous for applications that detect rare EV. Other important parameters are the detectable concentration range, the required sample volume, whether simultaneous presence of different antigens on a single EV can be detected, size selectivity of each assay and practical considerations. In this review, we will explain the working principles of the traditional and novel assays together with their performance parameters. The most sensitive assays are micro-nuclear magnetic resonance, surface plasmon resonance, and time-resolved fluorescent immunoassay.


Assuntos
Plaquetas/metabolismo , Western Blotting/normas , Ensaio de Imunoadsorção Enzimática/normas , Vesículas Extracelulares/metabolismo , Fluorimunoensaio/normas , Ressonância de Plasmônio de Superfície/normas , Biomarcadores/análise , Plaquetas/citologia , Western Blotting/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Vesículas Extracelulares/química , Fluorimunoensaio/instrumentação , Fluorimunoensaio/métodos , Humanos , Limite de Detecção , Ressonância Magnética Nuclear Biomolecular/instrumentação , Ressonância Magnética Nuclear Biomolecular/métodos , Ativação Plaquetária , Reprodutibilidade dos Testes , Ressonância de Plasmônio de Superfície/instrumentação , Ressonância de Plasmônio de Superfície/métodos
10.
Assay Drug Dev Technol ; 14(4): 240-51, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27136323

RESUMO

Glycosyltransferase enzymes play diverse metabolic and regulatory roles by catalyzing the transfer of sugar molecules to protein, lipid, and carbohydrate acceptors, and they are increasingly of interest as therapeutic targets in a number of diseases, including metabolic disorders, cancer, and infectious diseases. The glycosyltransferases are a challenging target class from an assay development perspective because of the diversity of both donor and acceptor substrates and the lack of suitable glycan detection methods. However, many glycosyltransferases use uridine 5'-diphosphate (UDP) sugars as donor substrates, and detection of the free UDP reaction product provides a generic approach for measuring the activity of those enzymes. To exploit this approach for a broadly applicable high-throughput screening (HTS) assay for discovery of glycosyltransferase inhibitors, we developed a Transcreener(®) assay for immunodetection of UDP with a time-resolved Förster resonance energy transfer (TR-FRET) signal. We optimized the assay for detection of glycosyltransferase activity with nucleotide diphosphate (NDP) sugars at concentrations from 10 µM to 1 mM, achieving Z' values of 0.6 or higher. The assay was validated by orthogonal pooled screening with 8,000 compounds using polypeptide N-acetylgalactosaminyltransferase T3 as the target, and the hits were confirmed using an orthogonal readout. The reagents and signal were both stable for more than 8 h at room temperature, insuring robust performance in automated HTS environments. The TR-FRET-based UDP detection assay provides a broadly applicable approach for screening glycosyltransferases that use a UDP-sugar donor.


Assuntos
Transferência Ressonante de Energia de Fluorescência/normas , Ensaios de Triagem em Larga Escala/normas , N-Acetilgalactosaminiltransferases/análise , N-Acetilgalactosaminiltransferases/metabolismo , Ligação Competitiva/fisiologia , Transferência Ressonante de Energia de Fluorescência/métodos , Fluorimunoensaio/métodos , Fluorimunoensaio/normas , Ensaios de Triagem em Larga Escala/métodos , Humanos , Projetos Piloto
11.
Anal Bioanal Chem ; 408(19): 5179-88, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27236318

RESUMO

The recent development of a homogeneous time-resolved Förster resonance energy transfer (TR-FRET) immunoassay enables one-step, rapid (minutes), and direct detection compared to the multistep, time-consuming (hours), heterogeneous ELISA-type immunoassays. The use of the time-resolved effect of a donor lanthanide complex with a delay time of microseconds and large Stokes shift enables the separation of positive signals from the background autofluorescence of the sample. However, this study shows that the sample matrices directly interfere with donor fluorescence and that interference cannot be eliminated by time-resolved settings alone. Moreover, the reduction in donor emission did not appear to be equivalent to the reduction in acceptor emission, resulting in incorrect FRET signal measurements. To overcome this limitation, an internal standard approach was developed using an isotype control antibody. This new approach was used to develop TR-FRET assays for rapid detection (15-30 min) of Bacillus anthracis spores and botulinum toxin (type E) in beverages, which are major concerns in bioterrorism involving deliberate food contamination. Additionally, we demonstrate the detection of B. anthracis-secreted protective antigen (PA) and the Yersinia pestis-secreted markers F1 and LcrV in blood cultures, which are early markers of bacteremia in infected hosts following a possible bioterror attack. The use of an internal standard enables the calculation of correct ΔF values without the need for an external standard. Thus, the use of the internal standard approach in homogeneous immunoassays facilitates the examination of any sample regardless of its origin, and therefore expands the applicability of TR-FRET assays for complex matrices.


Assuntos
Bactérias/isolamento & purificação , Bactérias/metabolismo , Toxinas Bacterianas/análise , Toxinas Bacterianas/normas , Técnicas de Tipagem Bacteriana/normas , Fluorimunoensaio/normas , Testes de Toxicidade/normas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Clin Chim Acta ; 439: 84-90, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25305537

RESUMO

BACKGROUND: High levels of circulating forms of the urokinase-type plasminogen activator receptor (uPAR) are significantly associated to poor prognosis in cancer patients. Our aim was to determine biological variations and reference intervals of the uPAR forms in blood, and in addition, to test the clinical relevance of using these as cut-points in colorectal cancer (CRC) prognosis. METHODS: uPAR forms were measured in citrated and EDTA plasma samples using time-resolved fluorescence immunoassays. Diurnal, intra- and inter-individual variations were assessed in plasma samples from cohorts of healthy individuals. Reference intervals were determined in plasma from healthy individuals randomly selected from a Danish multi-center cross-sectional study. A cohort of CRC patients was selected from the same cross-sectional study. RESULTS: The reference intervals showed a slight increase with age and women had ~20% higher levels. The intra- and inter-individual variations were ~10% and ~20-30%, respectively and the measured levels of the uPAR forms were within the determined 95% reference intervals. No diurnal variation was found. Applying the normal upper limit of the reference intervals as cut-point for dichotomizing CRC patients revealed significantly decreased overall survival of patients with levels above this cut-point of any uPAR form. CONCLUSIONS: The reference intervals for the different uPAR forms are valid and the upper normal limits are clinically relevant cut-points for CRC prognosis.


Assuntos
Receptores de Ativador de Plasminogênio Tipo Uroquinase/sangue , Receptores de Ativador de Plasminogênio Tipo Uroquinase/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluorimunoensaio/normas , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Fatores de Tempo , Adulto Jovem
13.
Allergy ; 70(2): 180-6, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25394543

RESUMO

BACKGROUND: Allergen-specific serum immunoglobulin E detection and quantification have become an important step in allergy diagnosis and follow-up. In line with the current trend of laboratory test accreditation to international standards, we set out to design and assess an accreditation procedure for allergen-specific serum IgE. METHODS: Method validation according to the accreditation procedure under the EN ISO 15189 standard was carried out for allergen-specific immunoglobulin E determination using the fluoroimmunoenzymatic method ImmunoCAP(®) (ThermoFisher). Data were produced by 25 hospital laboratories in France. A total of 29 allergen specificities including mixes, extracts, and molecular allergens were assayed. Allergen-specific serum immunoglobulin E concentrations ranged from 0.1 to 100 kUA /l. RESULTS: Repeatability, reproducibility, and accuracy results fulfilled method validation criteria for automated laboratory tests and proved similar irrespective of the allergen specificity, allergen-specific serum immunoglobulin E concentration, or individual laboratory. CONCLUSION: Allergen-specific serum immunoglobulin E determination with the fluoroimmunoenzymatic method ImmunoCAP(®) is a highly repeatable, reproducible, and accurate method which may be considered as a single analyte assay in view of the EN ISO 15189 accreditation procedure.


Assuntos
Alérgenos/imunologia , Fluorimunoensaio/métodos , Fluorimunoensaio/normas , Hipersensibilidade/diagnóstico , Hipersensibilidade/epidemiologia , Imunoglobulina E/imunologia , Humanos , Hipersensibilidade/imunologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Immunoassay Immunochem ; 35(3): 221-32, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24654819

RESUMO

In an effort to enhance the linear range of anti-CCP we developed a new immunoassay based on time-resolved fluoroimmunoassay. The precision, sensitivity, specificity, and stability of the assay were evaluated ELISA set as control. The anti-CCP IgG TRFIA kit we established had a wider detectable range than commercial ELISA ones. With regard to intra- and inter-assay precision, the TRFIA kit was better than threee commercial ELISA ones. The mean recovery rate was 101.0%. The TRFIA we developed for anti-CCP IgG detection yielded a more sensitive and reliable method for RA diagnosis and large-scale screening programs as well.


Assuntos
Artrite Reumatoide/diagnóstico , Autoanticorpos/sangue , Fluorimunoensaio/métodos , Peptídeos Cíclicos/imunologia , Animais , Artrite Reumatoide/sangue , Artrite Reumatoide/imunologia , Calibragem , Ensaio de Imunoadsorção Enzimática , Európio/química , Fluorimunoensaio/normas , Humanos , Imunoglobulina G/biossíntese , Imunoglobulina G/química , Imunoglobulina G/isolamento & purificação , Camundongos , Peptídeos Cíclicos/sangue , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos
15.
Anal Chim Acta ; 786: 132-8, 2013 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-23790302

RESUMO

The combination of stable biorecognition elements and robust quantum dots (QDs) has the potential to yield highly effective reporters for bioanalyses. Llama-derived single domain antibodies (sdAb) provide small thermostable recognition elements that can be easily manipulated using standard DNA methods. The sdAb was self-assembled on dihydrolipoic acid (DHLA) ligand-capped CdSe-ZnS core-shell QDs made in our laboratory through the polyhistidine tail of the protein, which coordinated to zinc ions on the QD surface. The sdAb-QD bioconjugates were then applied in both fluorometric and surface plasmon resonance (SPR) immunoassays for the detection of ricin, a potential biothreat agent. The sdAb-QD conjugates functioned in fluoroimmunoassays for the detection of ricin, providing equivalent limits of detection when compared to the same anti-ricin sdAb labeled with a conventional fluorophore. In addition, the DHLA-QD-sdAb conjugates were very effective reporter elements in SPR sandwich assays, providing more sensitive detection with a signal enhancement of ~10-fold over sdAb reporters and 2-4 fold over full sized antibody reporters. Commercially prepared streptavidin-modified polymer-coated QDs also amplified the SPR signal for the detection of ricin when applied to locations where biotinylated anti-ricin sdAb was bound to target; however, we observed a 4-fold greater amplification when using the DHLA-QD-sdAb conjugates in this format.


Assuntos
Pontos Quânticos , Ricina/análise , Ricina/imunologia , Anticorpos de Domínio Único/química , Ressonância de Plasmônio de Superfície/métodos , Fluorimunoensaio/métodos , Fluorimunoensaio/normas , Ligação Proteica/imunologia , Ricina/metabolismo , Ressonância de Plasmônio de Superfície/normas
16.
Arq. bras. endocrinol. metab ; 56(9): 658-665, Dec. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-660282

RESUMO

OBJECTIVE: In the last decade, data published stressed the role of highly-sensitive thyroglobulin (Tg) assays in the follow-up of differentiated thyroid carcinoma (DTC) patients. The present study describes a new, highly-sensitive Tg assay, compares it with an available commercial assay, and validates it in the follow-up of DTC patients. SUBJECTS AND METHODS: The immunofluorometric high-sensitivity Tg assay is based on monoclonal and polyclonal antibodies produced at our laboratories. It was validated in 100 samples of 87 patients with DTC submitted to total thyroidectomy, 87% of whom also received radioiodine. For correlation, all samples were also tested using a commercial Tg assay (Beckman Access) with functional sensitivity (FS) of 0.1 ng/mL. RESULTS: The new method showed FS of 0.3 ng/mL. The correlation between the two methods was good (r = 0.74; p < 0.0001). The diagnostic sensitivity was 88.9%, and it was increased to 100% when combined with neck US. CONCLUSION: This new, high-sensitivity Tg assay presented a good correlation with Beckman Access assay and with the clinical outcome of the patients. The continuous availability of a validated assay is an additional advantage for long term follow-up of DTC patients. Arq Bras Endocrinol Metab. 2012;56(9):658-65.


OBJETIVO: Na última década, estudos mostraram a importância dos ensaios de tiroglobulina (Tg) com melhor sensibilidade funcional no seguimento dos pacientes com carcinoma diferenciado de tiroide (CDT). Neste estudo, descrevemos o desenvolvimento de um novo ensaio de Tg de alta sensibilidade, que foi validado no seguimento de pacientes com CDT e correlacionado com um ensaio comercialmente disponível. SUJEITOS E MÉTODOS: O ensaio imunofluorométrico de Tg baseia-se em anticorpos, um monoclonal e um policlonal desenvolvidos em nosso laboratório. Avaliamos 100 amostras de soro de 87 pacientes com CDT submetidos à tiroidectomia total, sendo que 87% deles também receberam 131I. A Tg foi dosada também em ensaio comercial (Beckman Access). RESULTADOS: A correlação entre os dois métodos foi de 0,74 (p < 0,0001). O novo ensaio mostrou uma sensibilidade funcional de 0,3 ng/mL. A sensibilidade diagnóstica foi de 88,9%, que aumentou para 100% quando associada ao ultrassom cervical (US). CONCLUSÃO: O novo método de dosagem de Tg mostra boa correlação com o ensaio comercial Beckman Access e com a evolução clínica dos pacientes. O novo ensaio será fundamental no seguimento dos nossos pacientes com CDT. Arq Bras Endocrinol Metab. 2012;56(9):658-65.


Assuntos
Adulto , Idoso , Animais , Feminino , Humanos , Masculino , Camundongos , Pessoa de Meia-Idade , Coelhos , Adulto Jovem , Fluorimunoensaio/normas , Tireoglobulina/sangue , Anticorpos Monoclonais/biossíntese , Anticorpos Monoclonais , Fluorimunoensaio/métodos , Sensibilidade e Especificidade , Neoplasias da Glândula Tireoide/diagnóstico
17.
Arq Bras Endocrinol Metabol ; 56(9): 658-65, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23329190

RESUMO

OBJECTIVE: In the last decade, data published stressed the role of highly-sensitive thyroglobulin (Tg) assays in the follow-up of differentiated thyroid carcinoma (DTC) patients. The present study describes a new, highly-sensitive Tg assay, compares it with an available commercial assay, and validates it in the follow-up of DTC patients. SUBJECTS AND METHODS: The immunofluorometric high-sensitivity Tg assay is based on monoclonal and polyclonal antibodies produced at our laboratories. It was validated in 100 samples of 87 patients with DTC submitted to total thyroidectomy, 87% of whom also received radioiodine. For correlation, all samples were also tested using a commercial Tg assay (Beckman Access) with functional sensitivity (FS) of 0.1 ng/mL. RESULTS: The new method showed FS of 0.3 ng/mL. The correlation between the two methods was good (r = 0.74; p < 0.0001). The diagnostic sensitivity was 88.9%, and it was increased to 100% when combined with neck US. CONCLUSION: This new, high-sensitivity Tg assay presented a good correlation with Beckman Access assay and with the clinical outcome of the patients. The continuous availability of a validated assay is an additional advantage for long term follow-up of DTC patients.


Assuntos
Fluorimunoensaio/normas , Tireoglobulina/sangue , Adulto , Idoso , Animais , Anticorpos Monoclonais/biossíntese , Feminino , Fluorimunoensaio/métodos , Humanos , Masculino , Camundongos , Pessoa de Meia-Idade , Coelhos , Sensibilidade e Especificidade , Neoplasias da Glândula Tireoide/diagnóstico , Adulto Jovem
18.
PLoS One ; 6(1): e16741, 2011 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-21304970

RESUMO

We adapted DELFIA™ (dissociation-enhanced lanthanide fluoroimmunoassay), a time resolved fluorescence method, to quantitate whole venom specific and allergenic peptide-specific IgE (sIgE), sIgG(1) and sIgG(4) in serum from people clinically allergic to Australian native ant venoms, of which the predominant cause of allergy is jack jumper ant venom (JJAV). Intra-assay CV was 6.3% and inter-assay CV was 13.7% for JJAV sIgE. DELFIA and Phadia CAP JJAV sIgE results correlated well and had similar sensitivity and specificity for the detection of JJAV sIgE against intradermal skin testing as the gold standard. DELFIA was easily adapted for detecting sIgE to a panel of other native ant venoms.


Assuntos
Venenos de Formiga/imunologia , Fluorimunoensaio/métodos , Hipersensibilidade Imediata/diagnóstico , Imunoglobulina E/sangue , Imunoglobulina G/sangue , Alérgenos/imunologia , Austrália , Fluorimunoensaio/normas , Humanos , Imunoglobulina E/imunologia , Imunoglobulina G/imunologia , Mordeduras e Picadas de Insetos/imunologia , Sensibilidade e Especificidade
19.
J Virol Methods ; 172(1-2): 60-5, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21192976

RESUMO

Determination of varicella zoster virus (VZV) immunity in healthcare workers without a history of chickenpox is important for identifying those in need of vOka vaccination. Post immunisation, healthcare workers in the UK who work with high risk patients are tested for seroconversion. To assess the performance of the time-resolved fluorescence immunoassay (TRFIA) for the detection of antibody in vaccinated as well as unvaccinated individuals, a cut-off was first calculated. VZV-IgG specific avidity and titres six weeks after the first dose of vaccine were used to identify subjects with pre-existing immunity among a cohort of 110 healthcare workers. Those with high avidity (≥ 60%) were considered to have previous immunity to VZV and those with low or equivocal avidity (<60%) were considered naive. The former had antibody levels ≥ 400 mIU/mL and latter had levels < 400 mIU/mL. Comparison of the baseline values of the naive and immune groups allowed the estimation of a TRFIA cut-off value of > 130 mIU/mL which best discriminated between the two groups and this was confirmed by ROC analysis. Using this value, the sensitivity and specificity of TRFIA cut-off were 90% (95% CI 79-96), and 78% (95% CI 61-90) respectively in this population. A subset of samples tested by the gold standard Fluorescence Antibody to Membrane Antigen (FAMA) test showed 84% (54/64) agreement with TRFIA.


Assuntos
Anticorpos Antivirais/sangue , Varicela/prevenção & controle , Fluorimunoensaio/normas , Pessoal de Saúde , Herpesvirus Humano 3/imunologia , Vacinação , Adulto , Afinidade de Anticorpos/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
20.
J Vet Diagn Invest ; 23(1): 63-7, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21217029

RESUMO

In the current study, the quantification of C-reactive protein (CRP) in cerebrospinal fluid (CSF) of dogs using an adapted time-resolved immunofluorimetric assay (TR-IFMA) was investigated, as well as whether the assay could be used to detect the range of CRP concentrations found in different clinical situations. Intra- and interassay coefficients of variation were below 15% in all cases. The TR-IFMA measured the CRP values in a proportional and linear manner (r  =  0.99); also CRP concentrations measured in CSF and in serum were significantly correlated (r  =  0.80, P  =  0.003). The limit of detection of the method was 7.1 × 10(-6) mg/l. The assay was able to detect differences in CRP concentrations in CSF of dogs with inflammatory disorders compared with dogs with spinal cord compression or idiopathic epilepsy. In conclusion, TR-IFMA constitutes a very sensitive, precise, and accurate method for the measurement of CRP concentrations in CSF.


Assuntos
Proteína C-Reativa/líquido cefalorraquidiano , Doenças do Cão/líquido cefalorraquidiano , Fluorimunoensaio/veterinária , Animais , Cães , Fluorimunoensaio/métodos , Fluorimunoensaio/normas , Limite de Detecção , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...